System and Service Logs
From Firmware v0.15 the RockBLOCK Pro logs important events to a file named appLog.log persisting throughout reboots.
The log file includes the following:
First position fix, Modem connection, PPP connection, Signal Logging, High temperature logging, Iridium 97XX error codes.
Size​
The system and service log is set up to log until it reaches a size of 1MB, once the threshold is hit - it will be renamed to appLog.old and a new appLog.log will start fresh.
The size of the two files will never exceed 2MB.
Retrieving the log file​
Cloudloop Device Manager​
The System and Service log can be retrieved remotely via Cloudloop Device Manager.
danger
This will use IMT and your data allowance.