📣 Firmware Update:
Firmware Version 1.13.1 is now released! Please follow the link here or update via Cloudloop Device Manager.
Compliance
Compliance details for RockREMOTE and RockREMOTE Rugged​
The following references and compliance details are supported by test reports from accredited third party laboratories.
Region | Conformity | Reference | RockREMOTE compliant with: |
---|---|---|---|
United Kingdom | UKCA | Download DoC | See DoC |
Europe | CE | Download DoC | See DoC |
RED | 2.4GHz WAN - Iridium - LTE testing | ETSI EN 301 441: V2.1.1 (2016-06) | |
2.4GHz WAN - LTE testing | ETSI EN 300 328: V2.2.2 (2019-07) ETSI EN 301 908-1 V15.1.1:2021 | ||
GNSS testing | ETSI EN 303 413: V1.2.1 (2021-04) | ||
4G-LTE | ETSI EN 301 908-1: V15.1.1 (2021-09) | ||
EMC | EN 55035: 2017 A11: 2020, ETSI EN 301 489-1: V2.2.3 (2019-11), ETSI EN 301 489-17: V3.2.4 (2020-09), ETSI EN 301 489-52: V1.1.2 (2020-12) and ETSI EN 301 489-20: V2.2.1 (2021-11) | ||
Human exposure to RF EM fields | EN 50655 (at 1m distance 6 minutes or more) | ||
US | FCC | Refer to FCC Suppliers DoC below | |
Installed RF modules | Contains FCC ID: Q63-9770, RI7LE910CXNF and 2ABCB-RPICM4 | ||
2.4 GHz WLAN - LTE – Simultaneous Transmission | FCC 47 CFR Part 2 (2021), FCC 47 CFR Part 15 (2021), FCC 47 CFR Part 22 (2021), FCC 47 CFR Part 27 (2021) | ||
Unintentional Radiators | FCC 47 CFR Part 15B | ||
Human exposure to RF EM fields | FCC CFR Title 47 Part 1.1307 (at 1m distance) | ||
Canada | IC | Canada ISED compliance to CAN ICES-003(A) | |
Installed RF modules | Contains IC ID: 4629A-9770, 5131A-LE910CXNF and 11468A-CM4 / 11468ACM4 | ||
2.4 GHz WLAN - LTE – Simultaneous Transmission | ISED RSS-132: Issue 5 (2021), ISED RSS-199: Issue 3 (2016-12), ISED RSS-247: Issue 2 (2017-02) & ISED RSS-GEN: Issue 5 (2018-04) + A1 (2019-03) + A2 (2021-02) | ||
Unintentional Radiators | ICES-003 | ||
Human exposure to RF EM fields | ISED RSS-102 Issue 5 at 1m distance time averaging of 6 minutes | ||
Australia | ACMA | RCM marked (ABM 81145810206) | |
RF Exposure | In accordance with ARPANSA Radiation Protection Series S-1 | ||
All regions listed above | Safety | Third party tested to EN IEC 62368-1:2014 and IEC 60950-22(Outdoor - Rugged version only) | Minimum distance of 100 cm with ARPANSA Radiation Protection Series S-1 assuming continuous exposure of 6 minutes or more |
FCC Supplier's Declaration of Conformity
47 CFR § 2.1077 Compliance Information Unique Identifier: RockREMOTE (FP-RR-9770, FP-RR-RUGGED)
Responsible Party: Ground Control Systems 4650 Polaris Ave, Suite A, Las Vegas, Nevada 89103
This device complies with Part 15B of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.